Description
- Can be used to measure voltages up to 40V
- You can select the voltage range (5V, 15V or 40V) in software
- Automatic mode adjusts the range based on present voltage measurements
- Isolated for stability
When a 0-5V voltage input isn’t enough, the Phidget VINT 40V Voltage Input Module can be used to measure voltages up to 40V. You can select the voltage range (5V, 15V or 40V) in software; a smaller range results in higher precision. This Phidget also has an automatic mode that continuously adjusts the range based on present voltage measurements, so you’ll always have the most accurate measurement possible.
This Phidget is electrically isolated, so a power surge on the circuit you’re measuring will not damage your VINT Hub or your computer. Isolation also improves stability by eliminiating potential ground loops.
View moreLinks
PDF File
- Phidget VINT 40V Voltage Input Module Schematic
ZIP File
- Phidget VINT 40V Voltage Input Module Documentation
Specifications
Sensor Properties
- Sensor Type: Voltage (DC)
Board Properties
Voltage Sensor
- Withstand Voltage Max: 50 V DC
- Number of Voltage Inputs: 1
- Sensor Input Impedance: 1 M
- Voltage Difference Max: 40 V DC
- Sampling Interval Min: 40 ms/sample
- Sampling Interval Max: 60 s/sample
5V Range
- Voltage Resolution: 200 V DC
- Voltage Offset Max: 5 mV DC
- Measurement Error Max: 0.2 %
- Voltage Noise: 3 mV DC
15V Range
- Voltage Resolution: 500 V DC
- Voltage Offset Max: 15 mV DC
- Measurement Error Max: 0.2 %
- Voltage Noise: 10 mV DC
40V Range
- Voltage Resolution: 1.2 mV DC
- Voltage Offset Max: 40 mV DC
- Measurement Error Max: 0.2 %
- Voltage Noise: 25 mV DC
Electrical Properties
- Current Consumption Max: 11 mA
Physical Properties
- Recommended Wire Size: 16 – 26 AWG
- Operating Temperature Min: -40 C
- Operating Temperature Max: 85 C